Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

FIREROL Thin Wall Multipair Overall Screen Cables with Standrad Wall Sheath 300/500 V

EN 50306-4 (FRL-TW-05MP-SW-OS)

FIREROL FRL-TW-05MP-ESW-IOS

                                   A.Conductor      B.Insulation       C.Overall Screen         D.Sheath

Application

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles,

where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor

Tinned annealed copper wires as defined in EN 50306-2

Insulation

LSZH special compound

Overall screen

Tinned annealed copper wires

Pair Identification

Pairs numbered according to EN 50306-4

Outer sheath

LSZH special compound (S2. EM 101 - EM 104)

Electrical & Mechanical Properties

Nominal Voltage:300/500 V

Maximum Conductor Temperature:+90/+105 deg (fixed installation)

Minimum Permissible Ambient Temperature:-25/-40 deg (fixed installation)

Bending Radius:10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2:No fluorine

EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali

EN 50305:Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2:Hazard levels HL1, HL2/HL3

DIN 5510-2:Protection level 1/2/3/4

BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II

NF F 16-101:FO

EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
EN45545-2 Requirement for fire behavior of materials & components
R15/R16

FRL-TW-05MP-ESW-OS 300/500 V

Number of Pairs and Nominal Cross Section

Min. Thickness of Sheath at
any Point

Overall Diameter

 

Weight

Min.

Max.

N x n x mm2

mm

mm

mm

kg/km

2 x 2 x 0.5

0.56

6.6

7.9

61

3 x 2 x 0.5

0.56

7.0

8.1

78

4 x 2 x 0.5

0.56

7.7

8.7

96

7 x 2 x 0.5

0.56

9.0

10.6

146

 

2 x 2 x 0.75

0.56

7.1

9.0

80

3 x 2 x 0.75

0.56

7.7

9.2

103

4 x 2 x 0.75

0.56

9.0

10.0

128

7 x 2 x 0.75

0.56

10.8

11.8

200

 

2 x 2 x 1.0

0.56

7.8

9.5

95

3 x 2 x 1.0

0.56

8.3

9.7

125

4 x 2 x 1.0

0.56

9.1

10.3

156

7 x 2 x 1.0

0.56

11.0

12.4

247

 

2 x 2 x 1.5

0.56

9.8

11.2

126

3 x 2 x 1.5

0.56

10.4

11.4

168

4 x 2 x 1.5

0.56

11.6

12.6

212

7 x 2 x 1.5

0.56

14.0

15.3

340